TECHNICAL SPECIFICATIONS, SECTION 10155-TOILET COMPARTMENTS PART I - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and General Provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section.
1.2 SUMMARY
Acrystone® Solid Surface
A. This section includes manufactured toilet compartments.
B. Types of toilet compartments include:
Overhead Braced (XLFH)
Floor Mounted (XLF)
Ceiling Hung (CHF)
Floor to Ceiling Supported (XLFC)
C. Construction styles of toilet compartments include:
Floor Supported (FX)
Wall Hung (WH)
D. Construction styles of entrance and urinal screens include:
1.3 SUBMITTALS
A. General: Submit the following in accordance with Conditions of Contract and Division 1 Specification sections.
B. Product data for materials, fabrication, and installation including catalog cuts of anchors, hardware, fastenings, and accessories.
C. Shop drawings
for fabrication and installation of compartment assemblies that are not
fully described by architectural drawings. Provide template layouts and
installation instructions for anchorage devices built into other work.
D. Samples of full color range for each required unit type. Submit Tex-Lam's Acrystone® standard color selections.
1.4 QUALITY ASSURANCE
A. Field Measurements: Take field measurements prior to component fabrication to ensure proper fitting of work.
B. Coordination: Furnish inserts and anchorages that must be built into other work for installation of toilet compartments and related items.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
Subject to compliance with requirements, provide products by:
A. Tex-Lam Manufacturing, Inc., Houston, Texas 77091 (713) 695-5975.
2.2 MATERIALS
Acrystone® Solid Surface:
All
compartment material shall be manufactured of a non-porous Acrystone®
solid surfacing material. Acrystone® solid surface 1/8-inch (3mm)
sheets and edge strips are manufactured with acrylic resins,
ATH(aluminum tri-hydrate - a flame retardant mineral), and exclusive
pigments and particulates. All Acrystone® Solid Surface panels,
pilasters and doors are composed of medium density fiberboard bonded on
all sides and edges. Faces to be bonded under pressure with 7 wet mils
of non-flammable vinyl acetate rigid set adhesive. All edges to be
bonded physically and chemically with approved adhesive in conjunction
with solid surface seam adhesive to make seams inconspicuous. Finished
thickness of all panels, pilasters and doors to be 1-inch nominal.
A. General:
Provide material that has been selected for surface flatness and
smoothness. Exposed surfaces that exhibit seam marks, roller marks,
discoloration, telegraphing of core, or other imperfections on finished
units are not acceptable.
B. Select from the following:
C. Pilaster shoes: Shall be 18 gage Type 304 stainless steel, not less than 5-inches high, Number 4 Satin (brushed) finish.
D. Brackets:
Tex-Lam's standard design for attaching panels to walls, pilasters to
walls, and panels to pilasters shall be Type 304 stainless steel with
Number 4 Satin finish hardware.
E. Overhead Bracing:
Continuous extruded aluminum, anti-grip profile, with clear commercial
anodized finish. Head rail returns as shown on shop drawings.
F. Anchorages and Fasteners:
All concealed steel fasteners shall have a zinc-plated, rust-resistant,
coating. Exposed fasteners for Acrystone® Solid Surface shall be
stainless steel.
2.3 FABRICATION
A. General:
Furnish standard doors, panels, screens and pilasters fabricated for
compartment system. Furnish units with cutouts as required to receive
accessories as indicated.
B. Door Dimensions:
Unless otherwise indicated, furnish 24-inch wide in-swing doors for
ordinary toilet compartments and minimum 34-inch wide out-swing doors
for compartments that meet the requirements of the Americans with
Disabilities Act (ADA).
C. Restroom Compartments, Entrance and Urinal Screens:
Acrystone® Solid Surface:
Solid
surface material shall be processed and fabricated in a craftsman like
manner. All surfaces shall have a matte finish. Joints shall be tightly
bonded with an approved adhesive to minimize visible seams.
D. Construction Types of Toilet Compartments, Entrance Screens and Urinal Screens:
Overhead Braced (XLFH):
Furnish
aluminum supports and leveling bolts at pilasters to suit floor
conditions. Make provisions for setting and securing overhead bracing
at the top of each pilaster. Provide 5-inch height shoe at each
pilaster to conceal supports and leveling mechanism.
Floor Mounted (XLF):
Furnish
aluminum anchorage devices complete with threaded rod and leveling
adjustment nuts at pilasters to permit structural connection at floor.
Provide 5-inch height shoe at each pilaster.
Ceiling Hung (CHF):
Furnish
aluminum anchorage devices complete with threaded rods and leveling
adjustment nuts at pilaster connection for structural support above
finished ceiling. Furnish devices that are designed to support
pilasters from structure without transmitting load to finished ceiling.
Provide 5-inch height shoe at each pilaster to conceal anchorages.
Floor to Ceiling (XCHF):
Furnish
aluminum supports and/or threaded rod and leveling adjustment nuts at
pilasters as required. Provide 5-inch height shoes at each pilaster to
conceal anchorages.
E. Hardware: Furnish hardware to comply with ANSI A117.1 and Title III of the Americans with Disabilities Act (ADA) as follows:
Hinges:
Supply minimum stainless steel piano hinge Type 304 with Number 4 finish. Emergency access is available for outside access.
Latch and Keeper:
Type
304 stainless steel with Number 4 finish. Latching device shall consist
of a slide latch with combination stop and emergency release feature.
Coat Hook:
Type 304 stainless steel with Number 4 finish coat hook and/or combination coat hook and door bumper.
Door Pull:
Type 304 cast stainless steel with a Number 4 finish.
PART 3 - EXECUTION
1.1 INSTALLATION
A. General:
Comply
with manufacturer's recommended procedures and installation sequence.
Install compartment units rigid, straight, plumb and level. Provide
clearance of not more than ½-inch between pilasters and panels and not
more than 1-inch between panels and walls. Secure panels to walls with
not less than two brackets attached near top and bottom of panel.
Locate wall brackets so that holes for wall anchorages occur in masonry
or tile joints. Secure panels to pilasters with not less than two
brackets located to align with brackets at wall. Secure panels in
position with manufacturer's recommended anchoring devices.
B. Overhead Braced Compartments (XLFH):
Secure
pilaster to floor and level, plumb and tighten installation with
devices furnished. Secure overhead brace to each pilaster with
fasteners supplied. Hang doors and adjust so that tops of doors are
parallel with overhead brace when doors are in a closed position.
C. Floor Mounted Compartments (XLF):
Set
pilaster units with anchorages having not less than 2-inch penetration
into structural floor. Level, plumb and tighten installation with
devices furnished. Hang doors and adjust so that tops of doors are
level with tops of pilasters when doors are in closed position.
D. Ceiling Hung Compartments (CHF):
Secure
pilasters to supporting structure and level, plumb and tighten
installation with devices furnished. Hang doors and adjust so door
bottoms are level with bottoms of pilasters when in a closed position.
E. Floor to Ceiling Compartments (XLFC):
Secure
divider panels to built-in anchorage devices using concealed fasteners.
Level, plumb and tighten installation with devices furnished. Hang
doors and adjust so that bottoms of doors are 12-inch off floor when
doors are in a closed position.
F. Screens:
Attach
with anchoring devices as recommended by manufacturer to suit
supporting structure. Set unit to provide support and to resist lateral
impact.
1.2 ADJUST AND CLEAN
A. Hardware Adjustment:
Adjust and lubricate hardware for proper operation. Set hinges on
in-swing doors to hold open approximately 30 degrees from closed
position when unlatched. Set hinges on out-swing doors to return to a
fully closed position.
B. Clean and Protect:
Clean exposed surfaces of compartment systems using materials and
methods recommended by manufacturer, and provide protection as
necessary to prevent damage during remainder of construction period.